Ads 468x60px

Pages

Subscribe:

Labels

Informatica (18) Integration Service (10) Siebel Business Intelligence (6) ETL (5) Informatica PowerCenter (4) Informatica PowerCenter 8x (4) Oracle (4) Metadata (3) DTM (2) Data Transformation Manager (2) Hexaware Technologies (2) OUD (2) Oracle Unified Directory (2) PowerCenter (2) XML (2) business (2) ASCII (1) Administration Console (1) Application Services (1) Automated Migration (1) BFSI (1) Binary (1) Bulk Load (1) Business Intelligence (1) Business Intelligence Challenge (1) Business Intelligence Company (1) Business Intelligence Consulting (1) Business Objects (1) ByTree (1) CDC (1) CNBC News (1) CNBCTV18’s Shreya Roy (1) COBOL (1) Change Data Capture (1) Collaborative (1) Collaborative Data Management (1) Computing Expression Evaluator (1) Convert Rows To Columns In Inforamtica (1) Data (1) Data Governance (1) Data Management (1) Data Mart (1) Data Type (1) Data Virtualization Services (1) Database (1) Datawarehouse (1) ETL Developers (1) Expression Evaluator (1) Expression Evaluator Debugging (1) Extract (1) FTP (1) File List (1) Flash or Java Applets (1) Flat Files (1) Function (1) HP Diagnostics-Identify (1) HP Diagnostics-Identify bottlenecks (1) HTTP Headers (1) Hexaware Technologies Limited (1) IT Metrics (1) IT companies (1) IT company (1) Index (1) Indirect Source (1) Informatica 8.6 (1) Informatica 8.x (1) Informatica Data Integration Service (1) Informatica Debugger (1) Informatica Debugging Transformation (1) Informatica Development (1) Informatica File Transfer (1) Informatica Power Center (1) Informatica Powercenter 8x Key Concepts (1) Informatica Process Control Audit (1) Informatica Repository Restoration (1) Informatica Server Re-Installation (1) Informatica Server Recovery System (1) Informatica Upgrade Challenge (1) Informatica Workflow (1) Informatica Workflow Process Control (1) Integration Services (1) Integration and Repository services (1) Invalid Objects (1) JavaScript Functions (1) Joiner Transformation (1) LDAP (1) LDAP Directory (1) LDAP Replication (1) Load Balancer (1) LoadRunner 11.5 (1) Looping (1) Manual Correlation (1) Mappings (1) NTLM Resource (1) NTLM authentication (1) Native Driver (1) New Column (1) ODBC (1) ODBC Driver (1) OID (1) OUD Configuration (1) OUD Directory Server (1) OUD Replication (1) Oracle Applications (1) Oracle Client (1) Oracle Hints In SQL (1) Oracle Internet Director (1) Oracle Optimizer (1) Oracle R12 (1) Oracle Solutions (1) Oracle loadrunner (1) OracleErrorActionFile (1) PeopleSoft Jobs (1) PeopleSoft Jobs In Hexaware (1) Peoplesoft Tester In Chennai (1) Peoplesoft Tester Jobs In Chennai (1) Performance (1) Performance Testing (1) PowerCenter 8.5 (1) PowerCenter Server (1) PowerCenter Server Support (1) Powercenter 8.5.1 (1) Pushdown Optimization (1) Re-Import (1) Relational (1) Remote Filename (1) Repository Services (1) Reverse Of A Normalizer In Informatica (1) Rows Read (1) SFTP (1) SJSDS (1) SMP (1) SQL Statement (1) SSH2 (1) SUBSTR Function (1) Session Failed (1) Source Data (1) Source Definition (1) Source Row (1) Store Procedure (1) SuppressNilContentMethod (1) Symmetric Multi-Processing (1) Target Definition (1) Target Row (1) Task Developer (1) Text Flags (1) Transfer Protocol (1) Transformation (1) Transformation Logics (1) Transpose Records (1) UDF (1) User Defined Functions (1) WriteNullXMLFile (1) XML File (1) XML Optimization (1) XML Target (1) XML Tuning (1) XMLSendChildFirst (1) XMLWarnDupRows (1) Zero byte XML file (1) accelerate application (1) employee performance (1) mid-cap it (1) web_reg_save_param (1)

Labels

Blogroll

About

Blogger templates

Blogger news

Showing posts with label PowerCenter. Show all posts
Showing posts with label PowerCenter. Show all posts

Monday, 1 September 2008

Few tips related to Informatica 8.x environment


Let us discuss some special scenarios that we might face in Informatica 8.x environments.
A. In Informatica 8.x, multiple integration services can be enabled under one node. In case if there is a need to determine the process associated with an Integration service or Repository service, then it can be done as follows.
If there are multiple Integration Services enabled in a node, there are multiple pmserver processes running on the same machine. In PowerCenter 8.x, it is not possible to differentiate between the processes and correlate it to a particular Integration Service, unlike in 7.x where every pmserver process is associated with a specific pmserver.cfg file. Likewise, if there are multiple Repository Services enabled in a node, there are multiple pmrepagent processes running on the same machine. In PowerCenter 8.x, it is not possible to differentiate between the processes and correlate it to a particular Integration Service.
To do these in 8.x do the following:
1.      Log on to the Administration Console
2.      Click on Logs > Display Settings.
3.      Add Process to the list of columns to be displayed in the Log Viewer.
4.      Refresh the log display.
5.      Use the PID from this column to identify the process as follows:
UNIX:
Run the following command:
ps –ef grep pid
Where pid is the process ID of the service process.
Windows:
    1. Run task manager.
    2. Select the Processes tab.
Scroll to the value in the PID column that is displayed in the PowerCenter Administration Console.
B. Sometimes, the PowerCenter Administration Console URL is inaccessible from some machines even when the Informatica services are running. The following error is displayed on the browser:
“The page cannot be displayed”
The reason for this is due to an invalid or missing configuration in the hosts file on the client machine.
To resolve this error, do the following:
  1. Edit the hosts file located in the windows/system32/drivers/etc folder on the server from where the Administration Console is being accessed.
  2. Add the host IP address and the host name (for the host where the PowerCenter services are installed).
Example
10.1.2.10 ha420f3
  1. Launch the Administration Console and access the login page by typing the URL: http://<host>:<port>/adminconsole in the browser address bar.
It should be noted that the host name in the URL matches the host entry in the hosts file.

Read More about Informatica 8.x

Friday, 8 August 2008

Informatica and Stored Procedures


A. Described below is a scenario where the requirement is to have a stored procedure that returns a cursor as a source.By and large PowerCenter does not support a stored procedure that returns a cursor as a source. The workaround for this is1. The procedure that will load the data to a new table:
CREATE OR REPLACE procedure load (p_initial_date in date, p_final_Date in date) as
str_load varchar2 (500);
str_clean varchar2 (500);
begin
str_clean:= ‘DELETE FROM EMP’;
str_load:= ‘INSERT INTO EMP select * from EMPLOYEE where DOJ between trunc
(p_initial_date) and trunc (p_final_Date) ‘;
execute immediate str_clean;
execute immediate str_load;
EXCEPTION
WHEN OTHERS
THEN
ROLLBACK;
end load;
2. Create the table that will receive the data from the procedure:
SQL> create table EMP as SELECT * from EMPLOYEE where 1 > 2;
3. Add a Store Procedure transformation to the PowerCenter mapping. This transformation will execute this new procedure called as LOAD on this example.
4. Set the run method to be Source Pre Load, to be executed before read the source table.
5. Import the EMP table as a Source Definition. This table will be populated by the new Store Procedure.
If the original store procedure is used by the customer application and you can’t change the source code, you can create a new store procedure that call the original one (without inserting into a table), and execute the insert on the new table executing a loop on the returned cursor.
B. Given below is a situation where you wanted to pass a mapping variable to a stored procedure transformation (it can either be connected or unconnected).
Connected Stored Procedure
The parameters that are passed to a connected Stored Procedure have to be linked from another transformation.
Given below are the steps to pass mapping variable to a connected Stored Procedure transformation:
  1. Create an Expression transformation.
  2. Create an output port in the Expression transformation with the following expression:
$$mapping_variable
This sets the value of this output port to the mapping variable.
  1. Link this output port to the Stored Procedure transformation.
Unconnected Stored Procedure
For unconnected Stored Procedure transformations you can use the mapping variable in the expression calling the stored procedure.
Follow the steps below to pass mapping variable to a unconnected Stored Procedure transformation:
  1. Create an Expression transformation.
  2. Create an output port in the Expression transformation with the following expression:
: SP.GET_NAME_FROM_ID ($$mapping_variable, PROC_RESULT)
In case if you are attempting to use a mapping variable to store the output value of the stored procedure, the session will fail with the below error.
“TE_7002 Transformation Parse Fatal Error; transformation stopped: invalid function reference. Failed to Initialize Server Transformation.”
To resolve the issue replace the mapping variable with the PROC_RESULT system variable.
Example:
Incorrect, using a mapping variable:
:SP.PROCEDURE(FIELD1, $$mapping_variable)
Correct, using the PROC_RESULT system variable:
:SP.PROCEDURE(FIELD1,PROC_RESULT)
Or
:SP.PROCEDURE($$mapping_variable,PROC_RESULT)
The PROC_RESULT system variable assigns the stored procedure output to the port with this expression.
Read More about Informatica